PLUG & POWER™

RELOADED

New Solution

Welcome to PLUG & POWER™ RELOADED, our next generation solution for Power Distribution & Motor Control Centre panels. 10 years of design, development, client feedback and testing have produced a solution that combines flexibility, superior technical performance and unrivalled safety.

Select your Industry

Plug & Power™ Reloaded can be applied to any industry. Select an industry from the list to understand the benefits

Oil & Gas

The problem

Pump 2 down due to breaker fault

Fully withdrawable solution

Power maintained to other 3 pumps, breaker changed in 15 minutes.

Plug-in solution

Power maintained to other 3 pumps, breaker changed in 3 hours

Fixed type solution

Total loss of power to all pumps, 24 hours before operational

Healthcare

The problem

New MRI ward at hospital- additonal breakers required

Fully withdrawable solution

Power maintained to hospital, breaker added in 15 minutes.

Plug-in solution

Power maintained to hospital, breaker added in 3 hours

Fixed type solution

Total loss of power to hospital, 24 hours before operational

Manufacturing

The problem

Machine upgrades, new breakers required

Fully withdrawable solution

Power maintained to factory, new breaker added in 15 minutes.

Plug-in solution

Power maintained to factory, new breaker added in 3 hours

Fixed type solution

Total loss of power to factory, 24 hours before operational

Commercial

The problem

New store added at shopping mall

Fully withdrawable solution

Power maintained to mall, new breaker added in 15 minutes.

Plug-in solution

Power maintained to mall, new breaker added in 3 hours

Fixed type solution

Total loss of power to mall, 24 hours before operational

Renewable Energy

The problem

Damaged solar panels need to be replaced in a section

Fully withdrawable solution

Power maintained to remaining sections of photovoltaic panels, new breaker in 15 minutes

Plug-in solution

Power maintained to remaining sections of photovoltaic panels, new breaker added in 3 hours.

Fixed type solution

Total loss of power generated from entire solar farm, 24 hours before operational

Ice Cream

The problem

New compressor required at ice cream factory

Fully withdrawable solution

Power maintained to factory, new breaker added in 15 minutes.

Happy Children everywhere

Plug-in solution

Power maintained to factory, new breaker added in 3 hours

Shops full of ice cream

Fixed type solution

Total loss of power to factory, 24 hours before operational - loss of all ice cream at factory

Despair among local population

Key Features

  • Unified Basic Structure
  • Compact stacking density
  • Flexible cost
  • Front, Side & Rear cable access
  • Flexible configuration
  • Padlockable possible in the isolated position
  • Hot-swap function
  • Default form of internal separation up to 4b
  • Closed door operation for extra operator protection in all drawer positions, particularly in case of internal short-circuit and even during connecting and disconnecting
Max Units
40 (100 x 150)
Max Current Rating
2750 Amp
Access points
Rear, Side, Front

Cost Flexibility

With Plug & Power™ Reloaded you choose what you need. Use the slider below to change your panel configuration

0Maximum
Step 1
Basic unit type
Withdrawable
When constant power supply is essential
Plug-In
When minimum down time is permissible
Step 2
Power circuit configuration
Busbar System
Variable
Incoming Plug
Reliable up to 630A
Outgoing Plug
Connectivity of up to 4 No 240sqmm cables per phase
Step 3
Required accessories
Auxiliary Plug
For control and indication
Shutters
Safety for operator
Service Cover
Safety during maintenance
Posistion Indicator
Outstation connectivity and safety
Coding System
Maintains correct insertion position

Technical Features

  • Distribution busbars rated up to 2750A – 70ka 1 Second
  • ICC up to 100KA on Outgoing devices
  • Degree of protection IP 55
  • Rated Operation Voltage 415V & 690V
  • Up to 4 outgoing cables per phase 240 mm2
  • Up to 84 auxiliary contacts
  • Interchangeable power plugs
  • Interlock systems to prevent on-load disconnection

Fully Withdrawable

  • Lockable isolated position
  • Mechanical interlock to prevent removing/inserting on-load
  • Incoming and outgoing plugs
  • Up to 84 auxilary contact and digital communication are optional
  • Shutters, insertion interlock and position indicator are optional
  • IP2X in ”Test”, ”Isolated” and ”Removed” positions

Plug-in Technology

  • Individual or common door for plug-in units
  • Incoming plugs
  • Direct cable connection
  • Shutters are optional
  • Mechanical screw locked into position

Technical presentation

Watch Now